05704315 – Murphy Differential Pressure Swichgage – Model A20PE-OS-150

247,39

Murphy By Enovation – A20PE-OS-150: 2″ Pressure Swichgage; Internal Snap-Acting SPDT Switch; Oil Sealed; 0-150 Psi (05704315)

Swichgage® instruments are built in the USA and have protected engines and equipment in applications such as oil and gas, marine, irrigation, construction and trucking applications to monitor engine coolant, crankcase oil, transmission oil and others for more than 80 years.

The A20PE Swichgage is CSA listed for non-hazardous areas, and it features internal snap-acting SPDT switches, instead of the single pole/pointer contacts, for three wire control and can be wired to make or to break a circuit. When the switch closes on falling pressure, it becomes set, as pressure rises the switch resets.

Estimate available in 28 working days from Italy to Italy.

This product may vary on delivery times, as factories do not guarantee production due to lack of raw materials.

Availability: Available on backorder SKU: 05704315 Categories: , Tags: ,

Description

Product Specifications:

  • Dial: White on black, dual scale (U.S.A. standard scale is psi/kPa; U.K. standard scale is psi/bar)
  • Case: Polycarbonate / Glass filled, corrosion-resistant; steel mounting clamp included
  • Bezel: Polished stainless steel, standard; others are available
  • Lens: Polycarbonate, high impact
  • Temperature Range:
    • Ambient: -40° to 150° F (-40° to 66° C)
    • Process: -40° to 250° F (-40° to 121° C)
  • Process Connection: 1/8-27 NPTM brass
  • Sensing Element: Beryllium copper diaphragm
  • Gage Accuracy: ±3% maximum across scale
  • Adjustable Limit Contact: SPST contact; pilot duty only, 2 A @ 30 VAC/DC; closed when the low limit is met, open when pointer is in normal operating range. Contacts are gold flashed silver
  • Limit Contact Adjustment: by 1/16 in. hex wrench through 100% of scale
  • Wiring: A20P Number 4 screw terminals
  • Unit Weight: A20 Series: 0.23 kg
  • Unit Dimensions: A20 Series: 3 x 3 x 3 in. (76 x 76 x 76 mm)

Dimensions:

a20 series models dimension

Pressure Ranges and Factory Settings:

  1. Values in () are mathematical conversions from psi to kPa/MPa-they do not reflect actual second scale range. U.S.A. standard scale is psi/kPa;
  2. For models A20PE and A25PE; the switch trip point cannot be set at either the loe or high extreme of the scale. The trip point must allow for the reset differential.
  3. For adjustable switch models the trip point is adjustable only over the lower half of the scale.
Ranges AvailableMaximum PressureStandard SettingHigh Settings*A20PABS and A25PABS Setting
LowAlarm**
psi(kPa)[bar]psi(kPa)[bar]psi(kPa)[bar]psi(kPa)[bar]psi(kPa)[bar]
0-15(103)[1.0]30 psi (207)3(21)[0.2]12(83)[0.8]3(21)[0.2]6(41)[0.3]
0-30(207)[2.0]60 psi (413)7(48)[0.4]24(165)[1.6]7(48)[0.4]10(69)[0.6]
0-50(345)[3.5]100 psi (690)10(69)[0.8]40(276)[2.8]10(69)[0.8]13(90)[1.0]
0-75(517)[5.0]150 psi (1.0MPa)15(103)[1.0]60(414)[4.0]15(103)[1.0]18(124)[1.5]
0-100(690)[7.0]200 psi (1.4MPa)20(138)[1.5]80(552)[5.5]20(138)[1.0]23(159)[1.5]
0-150(1.0Mpa)[10]300 psi (2.1MPa)30(207)[2.0]120(827)[8.0]30(207)[1.5]33(228)[2.0]
0-200(1.4Mpa)[14]400 psi (2.8MPa)50(345)[3.0]150(1Mpa)[1.0]50(345)[3.0]53(365)[4.0]
0-300(2.1Mpa)[20]500 psi (3.4MPa)75(517)[5.0]225(1.6Mpa)[1.5]75(517)[5.0]78(538)[5.0]
0-400(2.8Mpa)[28]500 psi (3.4MPa)150(1.0Mpa)[7.0]300(2.1Mpa)[20]75(517)[5.0]150(1Mpa)[10]

*Low Setting for Hi/Lo option same as standard setting. Hi/Lo option avaible for A20P and A25P models only.**SPDT Snap-switch is the alarm switch.
**SPDT Snap-switch is the alarm switch.

Magnetic Switch

Inductive and high current loads require the use of a magnetic switch. The Swichgage contacts are for the light-duty electrical switching to operate alarms or control devices. Murphy manufactures the Magnetic Switch for protection of the pilot-duty Swichgage limit contacts.

Tattletale Magnetic Switches show the cause of shutdown for applications that include: capacitor discharge or magneto ignitions, battery systems and electric motor driven equipment. Typical wiring diagrams are show below.

magnetic switch a20p

Pre-Alarm Using A20/A25PABS

The A20PABS and A25PABS features a standard limit contact for equipment shutdown on low pressure. It also has an internal SPDT snap-switch to signal an alarm before shutting down. When the snap-switch trips (preset point), on falling pressure, the switch completes a circuit to activate an alarm. If the pressure continues to fall, the face-adjustable pointer contact will make and the shutdown circuit will be completed (see the typical diagram below for reference). The front contact shutdown limit setting (wich is adjustable) and the snap-switch are preset at the factory. Refer to “Pressure Ranges and Factory Settings” table on opposite page for setting. For alternative alarm before shutdown, see Magnetic Switch model 760A or 761APH.

pre alarm using a20-25pabs

Typical Internal Wiring Diagrams

Pointer shown in the shelf position. Pointer type contact rating: pilot-duty 2 A @ 30 VAC/VDC resistive.
Snap-acting switch rating: 3 A @ 30 VDC inductive. 4 A @ 125 VAC inductive.

a20p

How to order:

Base Model: A20PE
OS: Oil sealed (Silicone Oil)
150: 0-150 PSI; 0-1.03 kPa/MPa
Part Number: 05704315

Additional information

Weight0,23 kg
Brand

gtin

05704315, A20PE-OS-150